Heat recovery could save money and the environment

We are an online community created around a smart and easy to access information hub which is focused on providing proven global and local insights about sustainability

29 Apr, 2024

This post was originally published on Sustainability Matters

Compressors and the compressed air they generate are used in a multitude of applications. However, the fact that compressor exhaust heat can be harnessed often remains forgotten.

Up to 96% of the drive energy supplied to a compressor is available for reuse — this is referred to as “heat recovery”. Heat recovery not only saves energy and costs, but also reduces the operator’s CO2 footprint.

Of course, this heat could simply be conveyed away. However, there are plenty of ways to make use of this readily available energy source that occurs as a by-product of the compression process. The simplest and most efficient method is to use the compressor exhaust heat directly, eg, for heating adjoining rooms or spaces.

Here, instead of discharging hot air from the compressed air station outside, an air ducting system directs it to neighbouring warehouses or workshops. When no hot air is required, the heated exhaust air is simply conveyed outdoors by means of a flap or louvre. A thermostatically controlled louvre enables hot air to be provided as and when required in order to maintain a constant temperature.

Heated air from the compressor can be used for effective heating of neighbouring spaces via ducting.

In addition to providing full or supplementary heating for operating spaces, hot compressor exhaust air can be used to support applications such as drying processes, generating hot air curtains or preheating burner air for heating systems. The corresponding investment costs can often be amortised within a period of one year.

Compressor exhaust heat can also be used to supply existing hot water heating and service water systems; depending on the available storage capacity, water temperatures of over 70ºC can be generated.

There are several ways to achieve this. The most cost-effective method is to use a plate-type heat exchanger integrated into the compressor, which is connected to the compressor cooling fluid circuit and transfers energy from the heated cooling fluid to the water that requires heating. Depending on whether the hot water is required for particularly sensitive production or cleaning processes, for showering and washing, or for general heating systems, special safety heat exchangers or conventional plate-type heat exchangers may be used.

These enable 70–80% of the installed compressor output to be used for heating purposes without the need for any additional expenditure on energy. This variant of heat recovery is also possible with primary water-cooled rotary screw compressors. Heat recovery is principally worthwhile when the compressors in question feature a power output of at least 5.5 kW.

Establishing actual requirement

Since very few operators know their exact air demand, it is worth conducting a compressed air audit before installing a compressor system. Performed using analysis tools such as the ADA/KESS (Air Demand Analysis/Kaeser Energy Saving System), this audit can determine the precise demand data for a project. This data can then be used to determine the planning steps for the air station operator, as well as the investment costs and potential for energy savings.

In the case of a completely new installation, optimised solutions are devised and suggested from the outset so that the operator can independently compare different system variants and select the most cost-efficient choice.

Where building management systems are used, it is recommended to conduct a thermal audit in conjunction with the compressed air audit so that the heat balance can be determined in parallel with the air consumption. This allows thermal data such as temperature flow and return to be investigated in addition to compressed air data such as volume, pressure and required air quality.

Up to 96% of the energy used to generate compressed air can be recovered.

Once these details are established, it can be determined what percentage of the compressor exhaust heat can be absorbed into the normal heat requirement of the project. This in turn allows the size of the storage vessel and the required temperature to be calculated. In the best-case scenario, 96% of the heat output can be used.

What to consider:

A few points must be taken into account when planning or optimising a compressed air station. For example, compressors and heating systems should not be placed in the same room, since optimal use of these requires different room climate conditions and the compressor must not be permitted to draw in dangerous admixtures.

The compressor room needs to be well ventilated; the room for the heating system does not. In an ideal world, the two rooms would be separate but situated near to one another, so that the ducting route between compressors and heating system can be as short as possible.

Since the volume of accumulating heat and the heat requirement are rarely identical, it is important to ensure that there is sufficient thermal storage potential in the form of large vessels. This guarantees optimum supply when generation and consumption volumes differ.

Air- or water-cooled compressors?

Once the design has been decided, it is vital to select the correct compressors. In general, two different cooling methods are available for compressors: air cooling and water cooling.

In the case of the former, air ducts with thermostatically controlled flaps convey the hot exhaust air directly from the compressors to the neighbouring operating spaces. To minimise heat losses, the distance the exhaust air needs to travel from the compressor to the point of use should not be too far.

Even if it is not required year-round, heat recovery with this type of system pays dividends: the required investment for heat recovery is relatively low and can usually be amortised within just a year. Systems equipped with additional hot water heat recovery can supply water at temperatures up to 70ºC throughout the year, and even higher if needed.

In the case of water-cooled compressors, the user-end requirements and cooling water costs also play an important role; in principle, however, heat recovery as described above can also be achieved here by means of a second connected circuit.

Summary

Heat recovery can significantly increase the efficiency of a compressed air system and reduce environmental damage by preventing emissions of greenhouse gas.

For more information about KAESER heat recovery, visit: au.kaeser.com/products/rotary-screw-compressors/heat-recovery.

Top image caption: Heat recovery station. Image courtesy of Kaeser Compressors Australia.

Pass over the stars to rate this post. Your opinion is always welcome.
[Total: 0 Average: 0]

You may also like…

Navigating the supply chain for Scope 3 emissions

Navigating the supply chain for Scope 3 emissions

With more data centres transitioning to renewable energy sources, Scope 3 emissions become a data centre’s largest contributor to its greenhouse gas (GHG) emissions. This category of emissions is also the least reported and understood.

The focus on quantifying Scope 3 emissions in the value chain is part of a broader effort by organisations to assess and manage their environmental impact comprehensively. However, it requires a data-driven approach to helping data centre operators identify and categorise emissions from operations and the supply chain, then prioritise efforts to make impactful carbon reductions. This includes outsourced IT services from cloud and colocation service providers.

Undertaking this process allows for more informed decision-making and targeted efforts to reduce carbon emissions throughout the value chain. Developing a strategy that identifies the biggest source of carbon emissions in the value chain is quickly becoming a data centre industry priority, alongside the urgency to establish easy-to-use frameworks.

Data collection practices for a reporting framework

The effort to quantify and manage Scope 3 emissions aligns with broader trends in sustainability and corporate responsibility. Many organisations are recognising the importance of transparently addressing their environmental impact as part of their commitment to sustainable practices, but they don’t know where to start, which reporting framework to use, or how often they should be collecting and reporting data.

However, quantifying and reporting on Scope 3 presents a significant challenge for data centre operators. This is mainly due to a lack of three resources: reliable supplier data, quantitative tools, and an accounting and reporting methodology.

Establishing and implementing a framework that incorporates accurate carbon counting and target setting, while systematically reviewing company data and emission sources, is the foundation to creating an achievable reduction plan.

Electricity generation, GHG emissions and water consumption determine the carbon and water footprint of data centres, including that of its suppliers. To be successful, suppliers must provide data centre operators with their own Scope 3 emissions data, related to the products used in their data centres.

These emissions vary significantly depending on many factors including data centre size, redundancy level, location, electricity emission factor, core and shell construction, IT equipment configuration, energy efficiency, equipment lifespan and replacement frequency, and value chain activities.

Sustainability reporting can provide a competitive advantage

The proactive stance of data centre operators towards achieving net-zero climate goals reflects a broader shift in business attitudes toward sustainability. As environmental concerns become more prominent, companies are recognising the need to align their operations across the value chain with climate goals to meet the expectations of a diverse range of stakeholders including customers, investors and vendors, and contribute to a more sustainable future.

Aside from being a compliance necessity, GHG reporting encompassing Scope 3 emissions is increasingly being recognised as a strategic and beneficial practice for the data centre industry. It aligns with the growing emphasis on sustainability, helps manage risks, and positions companies as responsible and forward-thinking entities in an environmentally conscious market.

Robust emissions reporting can enhance investor confidence and attract investment from those seeking sustainable and responsible opportunities. Data centres that prioritise emissions reduction and extend their sustainability efforts to their supply chains can provide a competitive edge. A resilient and sustainable supply chain can contribute to business continuity and enhance the overall reputation of a company.

Vendor commitment to reducing embodied carbon

Scope 3 emissions are by far the most challenging to report for data centre operators who should integrate sustainability into their evaluation criteria when selecting data centre equipment suppliers and service providers to minimise Scope 3 value chain carbon footprint.

Vendors need to commit to reducing the embodied carbon of their product portfolio. Finally, data centre equipment suppliers must make environmental product disclosure documents freely available and easily understandable for their products.

By actively seeking equipment suppliers and service providers committed to reducing their environmental impact, data centre operators can play a crucial role in mitigating the overall carbon footprint associated with their operations related to Scope 3 emissions. The call for transparency and the availability of environmental product information further enhances the ability to make sustainable choices in the selection of data centre equipment.

Many organisations have focused on measuring and reporting Scope 1 and 2 emissions associated with their IT resources and implementing strategies to reduce them. Knowing where to start on your Scope 3 emissions metrics journey can be daunting. By quantifying Scope 3 emissions from their value chain, organisations can measure their total carbon footprint, including outsourced IT services from cloud and colocation service providers. Organisations can then prioritise their efforts to make impactful carbon reductions.

Schneider Electric offers many resources and tools to help organisations define Scope 3 emissions, including an inventory of nine emissions source categories and their data centre-specific subcategories for accounting and reporting purposes. This includes a modelling tool to simulate and model energy consumption within data centres that can help to estimate associated CO2 emissions. It also considers other factors such as power consumption, cooling systems, and overall data centre efficiency.

Its supply chain decarbonisation services help users leverage technology to measure and model resource use in the supply chain, educate and engage supplier partners, and support actions to decarbonise supplier operations.

By following these initial steps, data centres can expand their understanding of Scope 3 emissions and implement the right tools and measurement practices to work towards reducing their overall environmental impact and meeting reporting requirements with improving results.

Joe Craparotta

Top image credit: iStock.com/kohei_hara

Investing in Resilience: Blue Carbon Ecosystems, Communities, and Finance for the Indo-Pacific

Investing in Resilience: Blue Carbon Ecosystems, Communities, and Finance for the Indo-Pacific

Investing in Resilience: Blue Carbon Ecosystems, Communities, and Finance for the Indo-Pacific

Teaser Text
USAID’s “Investing in Resilience” report brings together the evidence and analyses that can help guide USAID Mission staff, partners, host country governments, and communities to advance blue carbon initiatives in the Indo-Pacific region.

jschoshinski
Tue, 11/12/2024 – 21:43

Publication Date
11/12/2024

Sectors

Natural Climate Solutions
Climate Finance

Country

Fiji
Kiribati
Republic of the Marshall Islands
Federated States of Micronesia
Nauru
Papua New Guinea
Philippines
Solomon Islands
Tonga
Tuvalu
Vanuatu
Micronesia

Region

Asia

Hide Sidebar
Off

0 Comments